  • Welcome to Chongqing Guote Medical Equipment Co., Ltd

    Product

    GP730 fully automatic computer vision instrument

    Classic testing program Threshold program: 10-2, 24-2, 30-2, Macula (macula), 60-4, nasal staircase Upper threshold value program: C-40, C-76, P-60, nasal step, FF-81, FF-120, FF-135 Special Program: Esterman Single Eyed (Driver Program), Superior36 Goldmann III Vision Reliability assurance Heiji Krak...

    • Comprehensive fixed vision monitoring
      Satisfy horizontal 150 ° visual field inspection
      Efficient inspection strategy
      Scientific and comprehensive analysis software

    Overview

    Parameter

    Classic testing program
    Threshold program: 10-2, 24-2, 30-2, Macula (macula), 60-4, nasal staircase
    Upper threshold value program: C-40, C-76, P-60, nasal step, FF-81, FF-120, FF-135
    Special Program: Esterman Single Eyed (Driver Program), Superior36
    Goldmann III Vision
    Reliability assurance
    Heiji Krakau physiological blind spot monitoring
    Real time video monitoring
    Automatic measurement of pupil diameter helps you effectively avoid the impact of pupil effect on visual field detection
    Efficient inspection strategy
    The application of interactive operations combined with intelligent analysis strategies makes detection more efficient without reducing the accuracy of detection results. The threshold testing program within the 30 ° range can be completed in just over 3 minutes, and it brings you high-quality inspection reports.
    Driver's monocular field of view inspection procedure
    The design principle of this program is based on the American standard driver inspection program and adds a horizontal field of view inspection range (160 °)
    Nasal visual field examination range: 72 °
    Temporal visual field examination range: 90 °
    Upper visual field examination range: 40 °
    Scope of visual inspection below: 60 °



    Regarding the correct scope of visual inspection in Order 139 of the Ministry of Public Security:
    A monocular horizontal field of view reaching 150 degrees (checking only the horizontal line of view is not enough, the upper and lower fields of view should also meet the requirements):
    Above view reaches 40 °
    View below reaches 60 °
    Big data pattern analysis
    VFI Field of View Index Analysis
    Single/multi view analysis
    Half field analysis of GHG glaucoma
    Analysis of glaucoma progression






     



    Application of visual field for glaucoma
    SWAP short wavelength visual field examination:
    Glaucoma causes damage to color vision earlier in the short wavelength range, and early glaucoma often selectively damages the blue cone cells.
    Glaucoma half field analysis:
    The field of view analysis method specifically designed for glaucoma divides the upper and lower half of the field of view into 5 corresponding areas in the central 30 ° area, with the horizontal meridian as the boundary. By comparing the corresponding areas and using different discrimination criteria, it indicates whether the field of view is within the normal range, boundary, general sensitivity decline, or beyond the boundary.


    Analysis of glaucoma progression:
    Compare the first two results of several visual field examinations performed by patients at different times with the baseline, and the subsequent results (up to 14 times) with the baseline, create a probability map of changes, and calculate the significance level of MD changes. Progress analysis provides point-to-point comparative analysis, allowing for the analysis of smaller visual field defects, thereby detecting changes in visual field earlier.
    Personalized design
    Multiple language versions available for users from all over the world
    Provide a familiar language environment;
    Customized program features allow you to create personalized views
    Wild testing mode to meet your special diagnostic needs.



    Quality comes from details
    Smooth coatings are used on the areas in contact with the human body to provide a comfortable touch for the examinee;
    The curved concave design of the field of view eye mask makes the wearer comfortable without affecting the field of view;
    The design of the cheek rest and forehead adopts ergonomic design, making the subject's head posture comfortable during the detection process.
    Unprecedented ease of operation
    The operation process adopts a one-stop design, easy to click, and one step in place
    The operation mode adopts a modular design, which is easy to learn and use, and only takes 3 minutes to learn and use