<tt id="4mmmm"><dd id="4mmmm"></dd></tt>
  • <tt id="4mmmm"></tt>
  • Welcome to Chongqing Guote Medical Equipment Co., Ltd

    Product

    GP750 fully automatic computer vision instrument

    Goldmann III Vision Comprehensive fixed vision monitoring Heiji Krakau physiological blind spot monitoring Real time video monitoring Gaze tracking Head position tracking Automatic measurement of pupil diameter helps you effectively avoid the impact of pupil effect on visual field detection. Efficient inspection s...

    • Comprehensive fixed vision monitoring
      Satisfy horizontal 150 ° visual field inspection
      Efficient inspection strategy
      Scientific and comprehensive analysis software

    Overview

    Parameter

    Goldmann III Vision
    Comprehensive fixed vision monitoring
    Heiji Krakau physiological blind spot monitoring
    Real time video monitoring
    Gaze tracking
    Head position tracking
    Automatic measurement of pupil diameter helps you effectively avoid the impact of pupil effect on visual field detection.
    Efficient inspection strategy
    The application of interactive operations combined with intelligent analysis strategies makes detection more efficient without reducing the accuracy of detection results, 30 °
    The threshold testing program for the scope can be completed in just over 3 minutes and provide you with high-quality inspection reports.
    Driver's monocular field of view inspection procedure
    The design principle of this program is based on the American standard driver inspection program and adds a horizontal field of view inspection range (160 °)
    Nasal visual field examination range: 72 °
    Temporal visual field examination range: 90 °
    Upper visual field examination range: 40 °
    Scope of visual inspection below: 60 °



    Regarding the correct scope of visual inspection in Order 139 of the Ministry of Public Security:
    A monocular horizontal field of view reaching 150 degrees (checking only the horizontal line of view is not enough, the upper and lower fields of view should also meet the requirements):
    Above view reaches 40 °
    View below reaches 60 °
    Scientific and comprehensive analysis software
    Big data pattern analysis
    VFI Field of View Index Analysis
    Single/multi view analysis
    Half field analysis of GHG glaucoma
    Analysis of glaucoma progression



    Application of visual field for glaucoma
    SWAP short wavelength visual field examination:
    Glaucoma causes damage to color vision earlier in the short wavelength range, and early glaucoma often selectively damages the blue cone cells.
    Glaucoma half field analysis:
    The field of view analysis method specifically designed for glaucoma divides the upper and lower half of the field of view into 5 corresponding areas in the central 30 ° area, with the horizontal meridian as the boundary. By comparing the corresponding areas and using different discrimination criteria, it indicates whether the field of view is within the normal range, boundary, general sensitivity decline, or beyond the boundary.


    Analysis of glaucoma progression:
    Compare the first two results of several visual field examinations performed by patients at different times with the baseline, and the subsequent results (up to 14 times) with the baseline, create a probability map of changes, and calculate the significance level of MD changes. Progress analysis provides point-to-point comparative analysis, allowing for the analysis of smaller visual field defects, thereby detecting changes in visual field earlier.


    Please leave us a message!

    Consultation

    86-23-68614805 86-23-68614806

    Service

    86-23-68614801

    Working:Weekday 9:00-17:00

    重慶國特醫療設備有限公司

    WeChat Official Accounts

    亚洲日韩欧美一区二区三区_丰满少妇人妻无码_99久久99久久免费精品小说_亚洲AV成人无码久久精品老人